V60-3 Hydrocarbon Hydronic Heating Air Sourced Heat Pump
For heating up to about 480sqm floorspace for panel radiators (55oC)
For heating up to about 600sqm floorspace for slab heating (45oC)
Our V60-3/V60-3ZA Hydrocarbon Hydronicss Heat Pump is purpose-built to heat water for hydronic heating systems
The cabinet and refrigeration system is pre-assembled to our design.
We finish them locally,charge them with Hydrocarbons, then fine-tune and put each heat pump through quality assurance testing.
Over the years we have developed our own inhouse heatpump tuning/monitoring rig.
Every machine that leaves our factory has been fine-tuned for its application, has been "run-in" for hours, and is shipped with its own performance guarantee. When it is delivered and installed, it will work faultlessly from day one.
The V60-3 can heat water to a maximum of 55oC, hot enough for panel radiator systems (recommend design for 55/45oC for new radiator installations), and can be user-programmed for under-floor/slab-heating temperatures, using a quality, easy to use backlit LCD panel.
See below for tips on sizing your heatpump for MAXIMUM EFFICIENCY AND SERVICE LIFE!
Technical data:
- Nominal input power: 15.5kW
- Voltage: 380/415V, (3ph)
- Pipe size: DN50
- Max outlet water: 55oC
- Environment range: -19oC to +45oC
- Compressor: 2x ZW108-KAE Copeland Scrolll
- Refrigerant: Hydrocarbons
- Weight:673Kg
- Sound Level: 75dBa (Low-Noise ZA fans optional)
- Dimension:1850x1000x1950mm
- Warranty: 3yrs *for all systems delivered after Jan 2017
Subject to suppliers sizing and installation guidelines being followed
*(there may be a travel charge for on-site service if there is a significant distance)
Specifications are subject to change without notice
Download data sheet
|
We use Natural Organic hydrocarbons:
Our hydronic heat pumps use hydrocarbon instead of traditional refrigerant, a highly efficient blend of R290 and R170, propane and ethane. When switching from R22, R502, R407C, and R404A power bills can be dramatically reduced, and the wear and tear on the refrigeration system can also be minimised.
It's the Natural Organic solution
Efficient and economical
- The superior efficiency of naturally occurring hydrocarbon gases, which are purified and precision blended, combined with reduced charge weight results in great cost savings and on-going electricity savings for the user.
Compliant with a number of national and international standards, such as: ISO 5149, the ISO/IEC 60335 series, BS 4434–1995 as well as AS/NZS 1677, which also covers the professional use of hydrocarbon refrigerants in Australia
|
|
Hi-Tech Low Noise Fan option
For up to 15% higher fan efficiency and especially for installations where sound level could be an issue, we recommend using super-efficient low-noise Ziehl-Abegg "Owlet" axial fans. |
Specifications are subject to change without notice
RRP $25,000* incl GST - We welcome trade enquiries! - 1300 552 976
plus delivery & installation * prices are subject to change without notice, so
please call
for latest pricing - special promotions etc.
Recommended Primary Circulation Pump for V60-3
We offer a small range of circulating pumps to suit a variety
of applications.
An essential part of any hydronic heating system is the circulating
pump or pumps.
The following table lists a range of circ. pumps to compliment
our Air Sourced Hydronic Heat Pumps as primary circuit pump
between the heat pump and the buffertank, and as the 'zone'
pump(s) which circulate the water between the buffertank and
the floorcoils and/or radiator panels.
The primary circulation pump must be matched to the flow-rate
required by the heat pump.
The secondary or zone pumps are usually 0.5 to 1.5 Litres
per second.
Some of our circulating pumps have 3 speeds to allow for varying
conditions:
|
Model
|
Body
|
Speed
|
Conn's
|
Head
|
Watts
|
Flow
Rate
|
R.R.P.
|
Comment
|
|
>GPD25-8<
|
C.I.
|
3 sp
|
25mm
|
8m
|
245
|
1.6L/s
|
|
hydronics zone pumps
|
|
PH-751QH
|
C.I.
|
1 sp
|
50mm
|
16m
|
900
|
5L/s
|
|
V60-3, NO HEAD, CLOSE-COUPLED
|
Recommend Purpose-made stainless steel buffertank
Other Hydrocarbon Hydronic Heat Pump Models:
Simplified rules for sizing your Skyline Energy hydrocarbon heatpump for hydronic heating
- for MAXIMUM EFFICIENCY AND SERVICE LIFE!
- Calculate how many kW are required
- Look at the climatology of the location to establish the duration of 0oC to +4oC. Don’t just look at the extreme temps, look at the mean overnight temp and duration
- If the ambient air temp rarely dips below +4oC or does so for short periods then you can use this simple calculation...
3.3 x electricity input kW = heatpump output heat kW to size the heatpump.
- If the mean overnight ambient air temp is between 0oC and +4oC change the calculation to
2.2 x electricity input kW = heatpump output heat kW to size the heatpump.
- A more powerful heatpump will raise the water temp more rapidly so it will cycle off before it needs to defrost,
thereby maintaining a higher COP and efficiency.
- Warranty service may be refused if our sizing guidelines are ignored.
|
MODEL |
POWER |
COMPRESSOR |
AIR |
5 STAR CAPABILITY |
|
|
QTY |
Brand Model |
DISCHARGE |
(5 star energy construction rating) |
220V 1ph |
>> SX-08 |
220V, 1ph |
1x |
Mitsubishi Rotary RN222VHFMC, 2.5HP |
1x fan - side |
up to 60sqm radiators or 75sqm slab |
>> SX-10 |
220V, 1ph |
1x |
Copeland ZR28K3E-PFJ-522, 2.33HP
|
1x fan - side |
for up to 75sqm radiators or 100sqm slab |
>> SX-12 |
220V, 1ph |
1x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
1x fan - side |
for up to 85sqm radiators or 120sqm slab |
>> SX-13CCZA |
220V, 1ph |
1x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
2x fan - side |
up to 100sqm radiators or 130sqm slab |
>> SX-15CCZA |
220V, 1ph |
1x |
Copeland ZR40K3E-PFJ-522, 3.33HP
|
2x fan - side |
up to 120sqm radiators or 150sqm slab |
>> SX-17CCZA |
220V, 1ph |
1x |
Copeland ZR47K3E-PFJ-522, 4.0HP
|
2x fan - side |
up to 140sqm radiators or 170sqm slab |
|
|
|
|
|
|
220V 1ph or 2ph (dual compressor) |
>> SX-21ZA |
220V, 1-2ph |
2x |
Copeland ZR28K3E-PFJ-522, 2.33HP
|
2x fan - top |
up to 160sqm radiators or 200sqm slab |
>> SX-24ZA |
220V, 1-2ph |
2x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
2x fan - top |
up to 200sqm radiators or 240sqm slab |
>> SX-26ZA |
220V, 1-2ph |
2x |
Copeland ZR36K3E-PFJ-522, 3.00HP
|
2x fan - top |
up to 220sqm radiators or 260sqm slab |
>> SX-30ZA |
220V, 1-2ph |
2x |
Copeland ZR40K3E-PFJ-522, 3.5HP
|
2x fan - top |
up to 250sqm radiators or 300sqm slab |
>> SX-34ZA |
220V, 1-2ph |
2x |
Copeland ZR47K3E-PFJ-522, 4.00HP
|
2x fan - top |
up to 280sqm radiators or 340sqm slab |
|
|
|
|
|
|
Can't find what you want - maybe we can build it for you - ASK!
Please call for trade pricing
For all enquiries, please call the national
number below
or email
NATIONAL DISTRIBUTION
CALL CENTRE:
1300 552 976
|